04 - First analog input

Prerequisite: Stage 3 accepted. Firmware: diagnostic-adc. Status: NOT TESTED.

Sequence overview | Exact contacts | 3D assembly

Add and test

Build only BB1 using MCP6002 and the exact placement/contact drawing. Keep ADC V2 at a known DC level. Check local decoupling, midpoint, then 1.5 V-biased 100 mVpp at 20, 100, 500 and 1000 Hz through the ADC; check 4000 Hz on the scope only (it is the 8 kHz Nyquist frequency). Keep generator output within 0.1-2.9 V including turn-on transients.

Acceptance checks

Send for review

Measure the voltage at the breadboard, not just the generator display: a 50-ohm setting into a high-impedance load can change delivered amplitude. Do not attach electrodes.

Continuous regression

Before power: inspect the changed wiring against the contact table and photograph it. After power: remeasure every connected rail at the load, verify no unexpected heat/current, and rerun the last accepted diagnostic. Repeat earlier affected tests whenever a supply, cable, firmware or grounding connection changes. Record failures and repairs; retain the previous accepted evidence.

If the gate fails

Stop acquisition and remove power before changing wiring. Disconnect only the last-added module and restore the last accepted configuration. Repeat its test. If it now fails, check the shared supply/ground and changed connections before replacing components. Never change multiple modules at once to chase a fault.

Results

Fill measurements.csv; retain raw instrument files alongside screenshots. Outcome starts NOT TESTED. Include units, uncertainty, instrument model/settings, source voltage/load, firmware hash and filenames. Mark unmet criteria FAIL; missing evidence PENDING. Submit the whole stage folder, including failures. A completeness check is not engineering approval.

Stage files