02 - Controller and controls

Prerequisite: Stage 1 accepted. Firmware: diagnostic-controller. Status: NOT TESTED.

Sequence overview | Exact contacts | 3D assembly

Add and test

Add controller, button, LEDs and USB sense. Connect only according to the existing exact contact table. Check 20 boots/programming cycles, then USB sense attached/absent. Measure the external 10k usb-pu (GPIO21 to 3V3D) with power off: the diagnostic enables an internal pull-up that can hide a missing resistor, and the recording firmware does not. Do not connect both external regulation and an unqualified DevKit USB power feed.

Acceptance checks

Send for review

The diagnostic intentionally allows instrumented USB operation. It does not itself prove the recording interlock; repeat the actual recording inhibition test at stage 7.

Continuous regression

Before power: inspect the changed wiring against the contact table and photograph it. After power: remeasure every connected rail at the load, verify no unexpected heat/current, and rerun the last accepted diagnostic. Repeat earlier affected tests whenever a supply, cable, firmware or grounding connection changes. Record failures and repairs; retain the previous accepted evidence.

If the gate fails

Stop acquisition and remove power before changing wiring. Disconnect only the last-added module and restore the last accepted configuration. Repeat its test. If it now fails, check the shared supply/ground and changed connections before replacing components. Never change multiple modules at once to chase a fault.

Results

Fill measurements.csv; retain raw instrument files alongside screenshots. Outcome starts NOT TESTED. Include units, uncertainty, instrument model/settings, source voltage/load, firmware hash and filenames. Mark unmet criteria FAIL; missing evidence PENDING. Submit the whole stage folder, including failures. A completeness check is not engineering approval.

Stage files